 ===== Sample Transport ===== ===== Sample Transport =====
  
-After collection the blood tubes are placed in a refrigerated (using ice packs), insulated transport box. The temperatures in these boxes are continuously monitored ([[logtag|LogTag TRIX-8]]) as part of our [[sample_quality|quality control]] procedures. These transport boxes are then shipped to the Lifelines laboratory, typically arriving between the hours of 10:00–12:00.+After collection the blood tubes are placed in a refrigerated and insulated transport box. The temperatures in these boxes are continuously monitored ([[logtag|LogTag TRIX-8]]) as part of our [[sample_quality|quality control]] procedures. These transport boxes are then shipped to the Lifelines laboratory.
  
 ===== Sample Reception ===== ===== Sample Reception =====
Line 43: Line 43:
 ==== Centrifuging ==== ==== Centrifuging ====
  
-  * 10.0 mL K2E (EDTA) 18.0mg Plus blood collection samples | 15 minutes @ 2500RCF and 4 degrees Celsius, no brake +  * 10.0 mL K2E (EDTA) 18.0mg Plus blood collection samples | 15 minutes @ 2500RCF and 4 degrees Celsius, full brake 
-  * 10.0 mL SST II Advance blood collection samples | 10 minutes @ 2500RCF and 18 degrees Celsius, no brake+  * 10.0 mL SST II Advance blood collection samples | 10 minutes @ 2500RCF and 18 degrees Celsius, full brake
  
 ===== Sample Processing ===== ===== Sample Processing =====
  
-Blood (plasma) and blood (serum) samples are divided into 900 μl fractions by the [[https://lifesciences.tecan.com/freedom-evo-packages|Tecan Freedom EVOware® robot]], a semi-automated system that combines pipetting, robotics, and scheduling of multiple devices.\\+Blood (plasma) and blood (serum) samples are divided into 900 μl fractions by a Hamilton robotics liquid handler, a semi-automated system that combines pipetting, robotics, and scheduling of multiple devices.\\
 These aliquots can be identified by a unique 2D barcode printed on the bottom of the tubes, and are held within a 1D barcoded rack ([[https://www.lvl-technologies.com/en/sample-storage/safe-2d-tubes-engl/safe-96-it-2D|LVL technologies Safe® 96 IT]] or equivalent). The exact location of each individual sample is logged and continuously tracked in our LIMS.\\ These aliquots can be identified by a unique 2D barcode printed on the bottom of the tubes, and are held within a 1D barcoded rack ([[https://www.lvl-technologies.com/en/sample-storage/safe-2d-tubes-engl/safe-96-it-2D|LVL technologies Safe® 96 IT]] or equivalent). The exact location of each individual sample is logged and continuously tracked in our LIMS.\\
 During sample processing special care is given to note deviations, such as hemolysis and lipemia, and to register these in our LIMS.\\ During sample processing special care is given to note deviations, such as hemolysis and lipemia, and to register these in our LIMS.\\