spirometry_validation
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
spirometry_validation [2021/05/06 15:25] – laura | spirometry_validation [2025/02/05 13:49] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 3: | Line 3: | ||
Researchers from the [[https:// | Researchers from the [[https:// | ||
- | The spirometry variables can be requested in the Lifelines catalogue or by mail (data@lifelines.nl).\\ | + | The spirometry variables can be requested in the [[https://data-catalogue.lifelines.nl/|Lifelines catalogue]].\\ |
===== Validation ===== | ===== Validation ===== | ||
- | [[Pulmonary Function Test|Spirometry]] is performed according to Standard Operating Procedures using the WEllch | + | [[Pulmonary Function Test|Spirometry]] is performed according to Standard Operating Procedures using the Welch Allyn SpiroPerfect device. Judgment on technical correctness is performed by a Lifelines assistant, a pulmonologist, |
* Test performed according to ATS criteria or | * Test performed according to ATS criteria or | ||
* Test not performed according to ATS criteria, but clinically reliable. | * Test not performed according to ATS criteria, but clinically reliable. | ||
In case both the pulmonologist and the Lifelines assistant judged the technical correctness, | In case both the pulmonologist and the Lifelines assistant judged the technical correctness, | ||
**Important: | **Important: | ||
- | \\ | + | |
=== Validation rules === | === Validation rules === | ||
To select only technically valid measurements the following rules were applied: | To select only technically valid measurements the following rules were applied: | ||
Line 21: | Line 21: | ||
|Other case|Spirometry is not technically correct| | |Other case|Spirometry is not technically correct| | ||
- | \\ | ||
- | \\ | ||
===== Reference values ===== | ===== Reference values ===== | ||
Reference values based on age, height, and sex are calculated based on the Global Lung Function Initiative (GLI) using the [[https:// | Reference values based on age, height, and sex are calculated based on the Global Lung Function Initiative (GLI) using the [[https:// | ||
- | |||
=== Remarks UMCG researcher === | === Remarks UMCG researcher === | ||
* It is important to note that ethnicity has not been taken into account. Everyone has been treated as Caucasian. | * It is important to note that ethnicity has not been taken into account. Everyone has been treated as Caucasian. | ||
- | * There are a few adults subjects with a huge difference in height between [[1a_visit_1|1A visit 1]] and [[2a_visit_1|2A visit 1]] resulting in a huge difference in reference values. It is recommended to exclude the adult subjects with a height difference of more than 5 cm using the height variable. | + | * There are a few adults subjects with a huge difference in height between [[1a_visit_1|1A visit 1]] and [[2a_visit_1|2A visit 1]] resulting in a huge difference in reference values. It is recommended to exclude the adult subjects with a height difference of more than 5 cm using the height variable.\\ |
+ | ===== Article ===== | ||
+ | * Mahon, G. M., Koppelman, G. H., & Vonk, J. M. (2021). Grandmaternal smoking, asthma and lung function in the offspring: the Lifelines cohort study. Thorax, 76(5), 441-447. DOI: 10.1136/ | ||
===== Variables ===== | ===== Variables ===== | ||
Line 57: | Line 55: | ||
| FEF75 % predicted | | FEF75 % predicted | ||
| FEF25_75 % predicted | | FEF25_75 % predicted | ||
- | | change in FEV1 2A versus 1A (liter per year) | verandering in FEV1 2A versus 1A (liter per jaar) | fev1_change_all_c_1 | + | | change in FEV1 2A versus 1A (liter per year) | verandering in FEV1 2A versus 1A (liter per jaar) | fev1_change_all_c_1 |
- | | change in FEV1FVC 2A versus 1A (liter per year) | verandering in FEV1FVC 2A versus 1A (liter per jaar) | fev1fvc_change_all_c_1 | + | | change in FEV1FVC 2A versus 1A (liter per year) | verandering in FEV1FVC 2A versus 1A (liter per jaar) | fev1fvc_change_all_c_1 |
- | | change in FVC 2A versus 1A (liter per year) | verandering in FVC1 2A versus 1A (liter per jaar) | fvc_change_all_c_1 | + | | change in FVC 2A versus 1A (liter per year) | verandering in FVC1 2A versus 1A (liter per jaar) | fvc_change_all_c_1 |
- | | change in FEF75 2A versus 1A (liter per second per year) | verandering in FEF75 2A versus 1A (liter per seconde per jaar) | fef75_change_all_c_1 | + | | change in FEF75 2A versus 1A (liter per second per year) | verandering in FEF75 2A versus 1A (liter per seconde per jaar) | fef75_change_all_c_1 |
- | | change in FEF25_75 2A versus 1A (liter per second per year) | verandering in FEF25_75 2A versus 1A (liter per seconde per jaar) | fef2575_change_all_c_1 | + | | change in FEF25_75 2A versus 1A (liter per second per year) | verandering in FEF25_75 2A versus 1A (liter per seconde per jaar) | fef2575_change_all_c_1 |
- | | difference in body length adults 2A versus 1A | verschil in lichaamslengte volwassenen 2A versus 1A | spirometry_bodylength_all_c_1 | + | | difference in body length adults 2A versus 1A | verschil in lichaamslengte volwassenen 2A versus 1A | spirometry_bodylength_all_c_1 |
spirometry_validation.1620314722.txt.gz · Last modified: (external edit)