User Tools

Site Tools


ecg

This is an old revision of the document!


12-lead electrocardiogram

Resting ECGs (section: physical state) were taken in Lifelines participants aged 13 years and older during:

Background

The 12-lead resting ECG measures electrical activity of the heart during rest, summarized in 12 leads.
The ECG provides many (>400) different variables at once, both quantitative and qualitative traits. These include duration, voltage and configuration characteristics. For example, information is provided of the cardiac rhythm, heart rate, the function of the sinoatrial and the atrioventricular node, atrial size, left ventricular mass, and repolarisation time (e.g. QT time).

Device

Welch Allyn CardioPerfekt Workstation ecg_manual.pdf
Welch Allyn CardioPerfect Workstation Software ecg_software_manual.pdf
DT100 vacuum units (suction electrode system).

Protocol

Electrodes were placed with conduction spray on ten clean spots at the abdomen and left side of the chest of lying participants (see illustration). In case of dextrocardia, the electrodes were mirrored.

All ECGs were checked by the research nurse and the Welch Allyn algorithm using CardioPerfekt software (see flow chart). ECG deviations (atrium fibrillation, atrium flutter, bradycardia, tachycardia, infoaction, acute ischemia, ST elevation, Wolff Parkinson White Syndrome, bigemenia, Left Bundle Branch Block, >1 premature ventricular contraction, second or third grade AV-block, pacemaker) were reported to a cardiologist.

Variables

The ECG resulted in the following variables:

English Variable Assessment Age
Automatic interpretation by Welch Allyn MEANS 1A 2A 13+
Remarks physician REM_CARD 1A 2A 13+
ECG to be manually reviewed REVIEW 1A 2A 13+
ECG manually reviewed? REVIEWED 1A 2A 13+
Evaluation BEOORDELING_A 1A 2A 13+
Conclusion CONCLUSIE_A 1A 2A 13+
Result ECGN_ID_A 1A 2A 13+
Heart Rate HR 1A 2A 13+
P-Wave P 1A 2A 13+
PQ-Time PQ 1A 2A 13+
QRS-Complex QRS 1A 2A 13+
QT-Interval QT 1A 2A 13+
QTc-Interval QTC 1A 2A 13+
P-Axis P_AXIS 1A 2A 13+
QRS-Axis QRS_AXIS 1A 2A 13+
T-Axis T_AXIS 1A 2A 13+
I Duration Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 IDURATION_1-6/15-20 1A 2A 13+
I Duration Lead X - Y - Z IDURATION_23-25 2A 13+
K Duration Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 KDURATION_1-6/15-20 1A 2A 13+
K Duration Lead X - Y - Z KDURATION_23-25 2A 13+
Q-Wave Duration Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 QDURATION_1-6/15-20 1A 2A 13+
Q-Wave Duration Lead X - Y - Z QDURATION_23-25 2A 13+
R-Wave Duration Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 RDURATION_1-6/15-20 1A 2A 13+
R-Wave Duration Lead X - Y - Z RDURATION_23-25 2A 13+
R'-Wave Duration Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 RACCDURATION_1-6/15-20 1A 2A 13+
R'-Wave Duration Lead X - Y - Z RACCDURATION_23-25 2A 13+
S-Wave Duration Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 SDURATION_1-6/15-20 1A 2A 13+
S-Wave Duration Lead X - Y - Z SDURATION_23-25 2A 13+
S'-Wave Duration Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 SACCDURATION_1-6/15-20 1A 2A 13+
S'-Wave Duration Lead X - Y - Z SACCDURATION_23-25 2A 13+
Largest negative deflection of the P wave Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 PNEGAMP_1-6/15-20 1A 2A 13+
Largest negative deflection of the P wave Lead X - Y - Z PNEGAMP_23-25 2A 13+
Largest positive deflection of the P wave Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 PPOSAMP_1-6/15-20 1A 2A 13+
Largest positive deflection of the P wave Lead X - Y - Z PPOSAMP_23-25 2A 13+
Largest negative T wave deviation Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 TNEGAMP_1-6/15-20 1A 2A 13+
Largest negative T wave deviation Lead X - Y - Z TNEGAMP_23-25 2A 13+
Largest positive T wave deviation Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 TPOSAMP_1-6/15-20 1A 2A 13+
Largest positive T wave deviation Lead X - Y - Z TPOSAMP_23-25 2A 13+
Q-Wave Amplitude Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 QAMP_1-6/15-20 1A 2A 13+
Q-Wave Amplitude Lead X - Y - Z QAMP_23-25 2A 13+
R-Wave Amplitude Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 RAMP_1-6/15-20 1A 2A 13+
R-Wave Amplitude Lead X - Y - Z RAMP_23-25 2A 13+
R'-Wave Amplitude Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 RACCAMP_1-6/15-20 1A 2A 13+
R'-Wave Amplitude Lead X - Y - Z RACCAMP_23-25 2A 13+
S-Wave Amplitude Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 SAMP_1-6/15-20 1A 2A 13+
S-Wave Amplitude Lead X - Y - Z SAMP_23-25 2A 13+
S'-Wave Amplitude Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 SACCAMP_1-6/15-20 1A 2A 13+
S'-Wave Amplitude Lead X - Y - Z SACCAMP_23-25 2A 13+
ST segment deviation at J point Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 ST0_1-6/15-20 1A 2A 13+
ST segment deviation at J point Lead X - Y - Z ST0_23-25 2A 13+
ST segment deviation 20 ms after the J point Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 ST20_1-6/15-20 1A 2A 13+
ST segment deviation 20 ms after the J point Lead X - Y - Z ST20_23-25 2A 13+
ST segment deviation 40 ms after the J point Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 ST40_1-6/15-20 1A 2A 13+
ST segment deviation 40 ms after the J point Lead X - Y - Z ST40_23-25 2A 13+
ST segment deviation 60 ms after the J point Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 ST60_1-6/15-20 1A 2A 13+
ST segment deviation 60 ms after the J point Lead X - Y - Z ST60_23-25 2A 13+
ST segment deviation 80 ms after the J point Lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 ST80_1-6/15-20 1A 2A 13+
ST segment deviation 80 ms after the J point Lead X - Y - Z ST80_23-25 2A 13+
You could leave a comment if you were logged in.
ecg.1635779798.txt.gz · Last modified: 2025/02/05 14:49 (external edit)