User Tools

Site Tools


hscrp

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
hscrp [2025/10/09 14:32] simonehscrp [2025/10/09 14:59] (current) simone
Line 10: Line 10:
  
 hscrp_result_all_m_1 and hscrp_result_all_m_2 only differ in the tube type. This has not affected the measured values (externally validated in N=100 samples). hscrp_result_all_m_1 and hscrp_result_all_m_2 only differ in the tube type. This has not affected the measured values (externally validated in N=100 samples).
-hscrp_result_all_m_1 and hscrp_result_all_m_2 differ from hscrp_result_all_m_3 in the supplier of the assay. This causes differences in the measured values. hscrp_result_all_m_1 and hscrp_result_all_m_2 values can be converted to hscrp_result_all_m_3 using the formula: //adjusted variable = 0.92 x unadjusted - 0.01//, that is //hscrp_result_all_m_3 = 0.92 x hscrp_result_all_m_1 – 0.01// and //hscrp_result_all_m_3 = 0.92 x hscrp_result_all_m_2 – 0.01//.+hscrp_result_all_m_1 and hscrp_result_all_m_2 differ from hscrp_result_all_m_3 in the supplier of the assay. This causes differences in the measured values. hscrp_result_all_m_1 and hscrp_result_all_m_2 values can be adjusted to be similar to hscrp_result_all_m_3 using the formula: //adjusted variable = 0.92 x unadjusted - 0.01//, that is //hscrp_result_all_m_1_adjusted = 0.92 x hscrp_result_all_m_1 – 0.01// and //hscrp_result_all_m_2_adjusted = 0.92 x hscrp_result_all_m_2 – 0.01//.
  
  
 **Please note:** **Please note:**
  
-- Until October 2025, this formula was displayed wrong on this wiki page. It mistakenly mentioned that difference in supplier did not have an effect on measured values, while difference in tube type did have an effect. This is the other way around. A wrong formula was displayed (//hscrp_result_all_m_1 = 0.92 x hscrp_result_all_m_2/3 – 0.01//)+- Until October 2025, this information was displayed wrongly on the wiki page. It was mistakenly mentioned that difference in supplier did not have an effect on measured values, while difference in tube type did have an effect. This is the other way around. A wrong formula was displayed (//hscrp_result_all_m_1 = 0.92 x hscrp_result_all_m_2/3 – 0.01//)
  
 - 3A hscrp_result_all_m_1 data was mistakenly released until May 2025.   - 3A hscrp_result_all_m_1 data was mistakenly released until May 2025.  
hscrp.1760020345.txt.gz · Last modified: by simone